Q&A and Discussion Forums

  • I would like to know the volume of treated water generated on an average per kilo litre of sewage water. I am asking this question to understand the loss of water (in %) with each treatment to get treated-water that can be used for gardens and toilet-reuse. Thank you, Srividya
    Anonymous (not verified)posted 1 year 3 months agoread more
  • I am a student of NIT Rourkela, and I plan to set up a carbonated water bottling (unflavored) company in Odisha, and need information regarding the same. Also, need some information regarding market status (demand and supply) of carbonated water in Odisha and nearby regions, along with information r...
    Anonymous (not verified)posted 1 year 3 months agoread more
  • Location: Warangal, Telangana Depth - 200ft 10ft to 45ft- Soild Rock 45ft to 55f - Weak soil + Water 55ft to 200ft Rock Casing - Till 60 ft - 8inch Dia (6mm PVC pipe ) 60ft to 200 -> 6 inch Dia no casing We drilled the borewell with above stats and after few months when we tried to install...
    Anonymous (not verified)posted 1 year 3 months agoread more
  • (Question received through email) I want to install greywater recycling system in my house. The treated water from which can be utilised for flushing in three toilets. Could please help me out. Also, please provide details of service provider of greywater recycling system installation, if any, in ...
    swatiposted 1 year 3 months agoread more
  • Hello, I am from Karnataka. I recently digged a borewell which is about 530 feet in depth and the water that was yielded is at 390 feet. I initially installed a 1HP pump 11 stages upto 190 feet depth which was not advisable by anyone. However, I still tried it because I didn't have water and I meas...
    Anonymous (not verified)posted 1 year 4 months agoread more
  • We have drilled borewell upto 400 ft but found no water, however, 3 to 4 days later we heard a noise of water. On measuring the water level by rope we found that the water level was at 150 foot. So, i would like to know that how much chances are there to have a good yield of water ?
    Anonymous (not verified)posted 1 year 4 months agoread more
  • I would like to get some estimate of the approximate water usage as per international standards for the following water utilisation by 18 hole golf course Guest rooms -164 rooms with 328 persons Resturant+Bar+Coffeshop - 1354 persons Banquet hall - 300 persons Spa - 20 persons Kindly, let m...
    Anonymous (not verified)posted 1 year 4 months agoread more
  • Hello, What is the required HP of the motor to pump the groundwater from around 180 ft (54.864 m) borewell ? Also, please suggest some motor pumps that I can check and buy - preferably with latest technologies. Along with this, I would like to know a resource or link for where I can check HP vs the...
    Anonymous (not verified)posted 1 year 4 months agoread more
  • Hello, We are an electronics assembly unit based in Gurgaon with employee strength of about 350. I wanted to understand the legal requirement for setting up a STP in our factory. Right now, our sewage is directly going to the municipal sewer line. We had taken pollution consent in 2016 when employe...
    Anonymous (not verified)posted 1 year 4 months agoread more
  • I have a 80 feet deep 4.5" borewell that is now inside a large room with RCC slap on top a 10 feet. This borewell had been supplying 24 hours of water with a one inch pump. However, of late the water in the borewell have reduced a lot. The technician says that we need to drill the well 250 feet deep...
    Anonymous (not verified)posted 1 year 4 months agoread more
  • Hello! I have a borewell of 270 feet depth deployed in my home in which I have put a submersible motor at a depth of 240 feet. While digging out that borewell we initially got water beyond 220 feet only. It was told that the areas surrounding our regions were rocks. In the due course of change in s...
    Anonymous (not verified)posted 1 year 4 months agoread more
  • We have a confectionery unit which releases effluent of 6ph. After primary treatment, the ph has reached to 8 in aeration tank but due to oxidation ph is gettinh low again to 6 automatically. Please suggest what to do.
    Anonymous (not verified)posted 1 year 4 months agoread more
  • I would like to know that if the drilling and casing for borewell is done initially, then can the pump motor be installed later? Will this affect my borewell in any way. Regarding the site, it is mostly sheet rock at hilly location with very few areas of loose soil.
    Anonymous (not verified)posted 1 year 4 months agoread more
  • I want to set up a RO water purifier for community under SHGs in a society in Saharanpur, Western Uttar Pradesh. Our community, especially women, are facing water quality issues. I would like to know how can I get financial assistance for setting up the community RO water purifier and is there any f...
    Anonymous (not verified)posted 1 year 4 months agoread more
  • The borewell was dug in May 2016. Total depth is 900 ft. Pump lowered to 780 ft. Yield 1.5 in. It was fine till June 2017. After the heavy rains in Bangalore, the water availability reduced. We suspected problem with the pump and tried to remove the pump. It was not possible to take it out. We suspe...
    Anonymous (not verified)posted 1 year 5 months agoread more
  • Would like to know the specifications, if any  for undesirable constituents in the treated sewage water used for gardening. Name:Venkatesh E-mail ID : venkateshav@hotmail.com
    aarti kelkar kh...posted 1 year 5 months agoread more
  • I'm currently studying in second year Civil Engineering undergraduate degree course. I wish to work in water resources management for India. What are the options available where I could serve effectively?  E-mail ID: chinud54@gmail.com
    Anonymous (not verified)posted 1 year 5 months agoread more
  • The water yeild in our borewell was around 1.25 inch at 570 sft. We further bored it upto 740 sft but there was no sign of second yeild. However, our neighbors got first yeild at 990 sft. We did not want to go further deep and hence we stopped at 740sft. The borewell is for domestic purpose. Now can...
    Anonymous (not verified)posted 1 year 5 months agoread more
  • Which GIS platform / software is best suited for evaluation of impact of watershed development on vegetation, cropping pattern and run off? Will Google Earth Engine serve the purpose or do we need to purchase GIS software like ArcGIS?
    Anonymous (not verified)posted 1 year 5 months agoread more
  • Our organization is coordinating a large scale watershed development program (>1000 villages). Who should conduct impact assessment of this program, an external agency or our internal team? What are the advantages and disadvantages of each?
    Anonymous (not verified)posted 1 year 5 months agoread more

Pages

I am from central Chennai and groundwater level in our area has drastically reduced, wo have to depend on other sources (Lorry and Metro water). Metro water often gets polluted so we are looking for control valve open/close by observing the flow through hand pump before letting it to the sump. The challenge here is metro water line to the sump is some 8 feet deep and we don't have proper provision to get down. Can someone please advice if we can have some control valve above the ground level by any means ?

Topics

Sub-Categories

Regions

Hi,

In our Apartment STP water quality gets affected regularly, when checked with AMC vendor we got to know that chemicals i.e paints, acid etc causes damage to STP. Please let me know whether really this kind of chemicals spoil the STP. If yes, please share the details of the chemicals/households chemicals.

Thanks, Saravanan Kumar K

Topics

Sub-Categories

Regions

Hi, We have done bore cleaning recently at depth of 340 Feet, and placed the borewell motor at 300 Ft. Now after cleaning the bore with compressor still the water is muddy. Could you please advise corrective action to be carried to get the water clean from borewell. Kindly advise possible solution to clean the borewell water if it does not get clean after bore the cleaning work.

Topics

Sub-Categories

Regions

Hi,

Topics

Sub-Categories

Regions

In Kerala, there was a devastating flood in the month of August. For a week or so it rained incessantly in the Western Ghats and on the plains. All the rivers were in spate. There were too many landslides on the hilly regions and the plains were under water for a week or so. When the flood waters finally receded and the region gained normalcy, a strange phenomenon was observed. The riverbed in many places have become sand dunes and the wells have become dry or the water table went down.

Topics

Sub-Categories

Regions

A 7.5 hp motor supplies to 06 number of G+3 building overhead tanks. At times, when few (say 04) buildings overhead tank are full, the pipeline system and motor gets pressurized due to supply to only 02 buildings. The pipe line is 2.5 inch dia. I have heard, variable speed motor may be helpful. Also, if someone can suggest auto shut/open system for such arrangement where there is supply from one motor is to 06 buildings.

Topics

Sub-Categories

Regions

Dear Sir,

Topics

Sub-Categories

Regions

Hello all,

We have 2 existing borewells as point marked by water dividers. We are not getting water from borewells. One of borewell has been dug upto the depth of 350 ft. We are getting very less water if we run motor once in a week. Please suggest either to go deeper on this or find new water points.

Location: 5 kms from Oragadam Sipoct towards Kanchipuram

Thanks in advance

Topics

Sub-Categories

Regions

The soakpit is getting filled quickly, especially during rainy season. As it has been happening regularly, we created a new tank recently. It is also filling in two days. Septic tank is ok now and require emptying once in two months. Could you provide any suggestion please ?

Topics

Sub-Categories

Regions

While drilling a borewell air gushed out of a nearby borewell, so we had to stop drilling. Please provide suggestion.

Topics

Sub-Categories

Regions

Pages